Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses
Air Mattresses

Air Mattresses

Stratus 1.1
⦁    20 individual and independent cell, which made of Nylon with polyurethane, closed with hermetic system and all in transversal position.
⦁    Sectioned cells in two parts. The lower part always stays in static mode and has 7 cm. of height, avoiding
⦁    that the contact between patient and bed.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Analogical control unit, intuitive and easily use.
⦁    Lower cover made of slip-resistant material to avoid that the mattress slides at the bed, furthermore it has straps to ensure the mattress to the bed.
⦁    Two-way stretch cover, with complete-zip divided in two sections away the mattress edges to prevent patient injuries and covered whit a wide flap to avoid liquid penetrations.
⦁    Therapies: Alternating
⦁    Modes: Low Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    8'5 Kg.
 
CONTROL UNIT
Dimensions    25’4x13x7’5 cm..
Weight    1'5 Kg.


Stratus 3.1
Replacement mattress designed for ulcers and shores prevention in high risk patients (grade I) according to Norton scale and to mitigate pressure ulcers until grade II according to EPUAP.

⦁    20 individual and independent cell, which made of Nylon with polyurethane, closed with hermetic system and all in transversal position.
⦁    Sectioned cells in two parts. The lower part always stays in static mode and has 7 cm. of height, avoiding
⦁    that the contact between patient and bed.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Analogical control unit, intuitive and easily use, with visual and acoustic low pressure alarm and normal pressure alarm, with silence option.
⦁    Lower cover made of slip-resistant material to avoid that the mattress slides at the bed, furthermore it has straps to ensure the mattress to the bed.
⦁    Two-way stretch cover, with complete-zip divided in two sections away the mattress edges to prevent patient injuries and covered whit a wide flap to avoid liquid penetrations.
⦁    Therapies: Alternating and Static
⦁    Modes: Low Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    8'5 Kg.
 
CONTROL UNIT
Dimensions    40x26x15 cm.
Weight    5 Kg.


Stratus 5.1
Replacement mattress designed for ulcers and shores prevention in high risk patients (grade I) according to Norton scale and to mitigate pressure ulcers until grade II according to EPUAP.

⦁    20 individual and independent cell, which made of Nylon with polyurethane, closed with hermetic system and all in transversal position.
⦁    Sectioned cells in two parts. The lower part always stays in static mode and has 7 cm. of height, avoiding that the contact between patient and bed.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Digital control unit with visual and acoustic low pressure alarm, power failure alarm and system failure alarm, with silence option.
⦁    Straps for ensuring the mattress to the bed, furthermore the mattress has slip-resistant zones under the mattress.
⦁    Two-way stretch cover, with complete-zip divided in two sections away the mattress edges to prevent patient injuries and covered whit a wide flap to avoid liquid penetrations
⦁    Therapies: Alternating and Static.
⦁    Modes: Max Firm, Fowler and Low Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    8'5 Kg.
 
CONTROL UNIT
Dimensions    40x26x15 cm.
Weight    5 Kg.

Stratus 7.1
Replacement mattress designed for ulcers and shores prevention in high risk patients (grade I) according to Norton scale and to palliate pressure ulcers until grade III according to EPUAP.

⦁    20 individual and independent cell, which made of Nylon with polyurethane, closed with hermetic system and all in transversal position.
⦁    Sectioned cells in two parts. The lower part always stays in static mode and has 7 cm. of height, avoiding that the contact between patient and bed.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Digital control unit with visual and acoustic low pressure alarm, power failure alarm and system failure alarm, with silence option.
⦁    Straps for ensuring the mattress to the bed, furthermore the mattress has slip-resistant zones under the mattress.
⦁    Two-way stretch cover, with complete-zip divided in two sections away the mattress edges to prevent patient injuries and covered whit a wide flap to avoid liquid penetrations.
⦁    Therapies: Alternating and Static
⦁    Modes: MaxFirm, Fowler and Low Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    8'5 Kg.
 
CONTROL UNIT
Dimensions    40x26x15 cm.
Weight    5 Kg.

Stratus 9.1
Replacement mattress designed to prevent the ulcers and shores in high risk patients (grade I) according to Norton scale and mitigate the pressure ulcers until grade IV according to EPUAP.

⦁    20 independents, interchangeable and microperforated cells, which are high resistance, made of Nylon/PU, closed with hermetic system and all in transversal position.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Digital control unit with visual and acoustic low pressure alarm and power failure alarm, with silence option.
⦁    The cells are over foam mat (5 cm.) with cover and air mat optional for protection of the patients while transfer them.
⦁    Dual cover, the two-way stretch exterior cover is the nylon with fire retardant polyurethane coating and the interior is made of Tafetta, both parts with full-zip divided in two sections
⦁    Therapies: Pulsation, Pulsanate, Alternating and Static.
⦁    Modes: Max Firm, Fowler and Los Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    12'7 Kg.
 
CONTROL UNIT
Dimensions    40x15x26'5 cm.
Weight    8'2 Kg.

 

Stratus Turn
Rotation air system designed to prevent the ulcers and shores in high risk patients (grade I) according Norton scale and mitigate the pressure ulcers until grade IV according to EPUAP.

⦁    20 Independents, interchangeable and microperforated cells, which are high resistance, closed with hermetic system, divided in two columns.
⦁    Lateral cells puts to avoid the fall of the patient while he is lateralized.
⦁    RCP emergency valve fitted on the upper mattress area. In case of emergency it allows to deflate mattress in 10 seconds.
⦁    Digital control unit with visual and acoustic low pressure alarm and power failure alarm, with silence option.
⦁    The cells are over air mat, which has 5 cm. of height, avoiding the patient contact with the bed.
⦁    Dual cover, the exterior cover is the nylon with fire retardant polyurethane coating and the interior is made of Tafetta, both parts with full-zip divided in two sections.
⦁    Therapies: Rotation, Pulsation and Static
⦁    Modes: Max Firm, Fowler and Low Air Loss

MATTRESS
Dimensions    85x200x20 cm.
Weight    12'7 Kg.
 
CONTROL UNIT
Dimensions    53x28x40 cm.
Weight    5 Kg.
 

 

 


Related Products

TechnoPlus Bed

TechnoPlus Bed

Atica Stretcher

Atica Stretcher

Bedside cabinet Salduba accessory

Bedside cabinet Salduba accessory